Addressable Smoke Alarm

Without Sound,Should work with the addressable fire alarm panel.

   
Photo Parameters Remarks
addressable fire alarm,smoke alarm

Addressable heat alarm, Model:AAH-1


1.Votage DC18~26V
2.Monitor current ≤350uA
3.Alarm current ≤1.5mA
4.Lamp(red) Run-time flash, alarm always
5.Operation temperature -10℃~+55℃
6.Relative humidity ≤95%
7.Outline Φ90×35mm
8.Weight 100g
9.Color Milky
10.Standard GB 4716-2005

Addressable, Matched with the AWR-A1 addressable alarm panel

addressable fire alarm,smoke alarm

Addressable smoke alarm, Model:AAS-1

1.Votage DC18~26V
2.Monitor current ≤350uA
3.Alarm current ≤1.5mA
4.Lamp(red) run-time flash, alarm always
5.Operation temperature -10℃~+55℃
6.Relative humidity ≤95%
7.Maximum air velocity ≤5m/sec
8.Outline Φ90×41.5 mm
9.Weight 100g
10.Color Milky
11.Standard GB 4715-2005

Addressable, Matched with the AWR-A1 addressable alarm panel

addressable fire alarm panel

Addressable fire alarm panel, Model:AWR-A1

Technical Specification
Main power AC 220V (+10%~-15%) ,50Hz
Emergency power DC 24V,4AH
Power monitor state:≤3W;alarm state:≤10W
Monitor capacity 2 loops,250 pcs every loop;
Output control terminal 5
Capacity of output control terminal DC 30V,1A;
Check period ≤10s
Signal transmint distance ≤1000米( RVS-2×1.0mm2 );
≤1500m( RVS-2×1.5mm2 );
Wiring mode Two-bus;
Wiring Not less then 2.5mm2
Votage between the alarm bus 24V (18V~26V)
Operation temperature 0℃~+55℃
Relative humidity ≤95%
Amount of the record in black casket Can save 999 records( incloud start、stop 、reset、fire alarm and fault etc. )
Amount of linkage programme 100( include or1、or2、and )
Amount of the detector's description 2×250 pcs,10 Chinese characters or 20 English characters every description
Fire alarm output delay 1( K1、K2 ),votage-free,close when fire alarm
Fault output delay 1( YA1、YA2 ) ,votage-free,close when fire alarm
Outline 480×380×100 mm3

AWR-A1 Panel: Matched with the AAS-1 addressable smoke alarm, and AHH-1 heat alarm.

Feature:

·Complete English, Portuguese, or Spanish display.
·History memory record function.
·500 bus component capacity.
·5 manual external control units.
·Two times transfer of alarm address information (Chinese or English input).
·Fire alarm control function with site programming.
·Send alarm information to fire repeater, CRT etc.
·quantification function of detector data.(no dimension)
·Automatic identification of bus equipment type.

1. Ultra thin structure, Low Power Consumption
2. Own CPU, Automatic identification of fire
3. 2-bus.no-polarity
4. Strong anti-humidity, can be used in the place with bigger interference.
5. Use address code programmer to write code instead of DIP switch.
AAS-1 is a point pattern photoelectric smoke detector which can work under the environment as the weather changes a lot. It can give a prompt response for the smoke generated at the very beginning of the fire. Generally, the detector is installed in the following vital places such as the office, sitting room, the hall, aisle, the storage, transformer cabin, the control room etc.
6. AAS-1 photoelectric smoke detector consists of 86 model embedded part, the base part, and so on.