Conventional Smoke Alarm
Conventional type smoke alarm are interconnected with the conventional fire alarm control panel.

It alerts when alarm send the NO/NC signal to the fire panel.

Please note: Conventional smoke alarms are all driven by the power from the panel. They do not include the power by themselves.

Generally, the conventional smoke alarms are without sound output, just a NO/NC signal to the control panel, and then the panel alerts.

 
Photo Parameters Remarks
smoke alarm, fire alarm1

Model:ACS-1

1.Power source: DC9V-28V
2.Stainless steel shield chamber,Anti-RFI;
3.SMT adopted,high stability.
4.Dustproof,mothproof and anti-light interference design.
5.MCU processing adopted,eliminate false alarm.
6.Static current:<2mΑ, Alarm current: <10mA
7.Working Temperature:-10~+50℃; RH:<95%
8.Output:Passive relay output(NO,NC)
9.Dimension: Φ104*51mm .
10.Execute criterion:GB4715,EN54-7,UL268,EN14604;UL217

 

Conventional type, Alarm with NO/NC signal ,Without sound output.

Photoelectric smoke detector including bracket;

smoke alarm, fire alarm2

Model:ACS-2

1.Power source: AC220V , DC 9V battery
2.Stainless steel shield chamber,Anti-RFI;
3.SMT adopted,high stability.
4.Dustproof,mothproof and anti-light interference design.
5.MCU processing adopted,eliminate false alarm.
6.Static current:<20mΑ, Alarm current: <35mA
7.Working Temperature:-10~+50℃; RH:<95%
8.Output:Sound 85dB/3m+Passive relay output(NO,NC)
9.Dimension: Φ104*38mm .
10.Execute criterion:GB4715,EN54-7,UL268,EN14604;UL217

Alarm with sound and NO/NC signal output;

Photoelectric smoke detector including battery and bracket;

smoke alarm, fire alarm3

Model:ACS-3

1.Power source: DC9V-24V
2.Stainless steel shield chamber,Anti-RFI;
3.SMT adopted,high stability.
4.Dustproof,mothproof and anti-light interference design.
5.MCU processing adopted,eliminate false alarm.
6.Static current:<2mΑ, Alarm current: <10mA
7.Working Temperature:-10~+50℃; RH:<95%
8.Output:Passive relay output(NO,NC)
9.Dimension: Φ104*49mm .
10.Execute criterion:GB4715,EN54-7,UL268,EN14604;UL217

 

Conventional type, Alarm with NO/NC signal ,Without sound output.

Photoelectric smoke detector including bracket;

smoke alarm, fire alarm4

Model:ACS-4

1.Power source:DC9V-28V
2.Stainless steel shield chamber,Anti-RFI;
3.SMT adopted,high stability.
4.Dustproof,mothproof and anti-light interference design.
5.MCU processing adopted,eliminate false alarm.
6.Static current:<200μΑ, Alarm current: <50mA
7.Working Temperature:-10~+50℃; RH:<95%
8.Output:Passive relay output(NO,NC)
9.Dimension: Φ104*48mm .
10.Execute criterion:GB4715,EN54-7,UL268,EN14604;UL217

 

Conventional type, Alarm with NO/NC signal ,Without sound output.

Photoelectric smoke detector including bracket;

smoke alarm, fire alarm5

Model:ACS-5

1.Power source: AC220V , DC 9V battery
2.Stainless steel shield chamber,Anti-RFI;
3.SMT adopted,high stability.
4.Dustproof,mothproof and anti-light interference design.
5.MCU processing adopted,eliminate false alarm.
6.Static current:<800μΑ, Alarm current: <35mA
7.Working Temperature:-10~+50℃; RH:<95%
8.Output:Sound 85dB/3m; 315/433 wireless signal; Code:2262/1527; Wireless distance: 100m
9.Dimension: Φ128*38mm .
10.Execute criterion:GB4715,EN54-7,UL268,EN14604;UL217

Alarm with sound and wireless signal output;

Wireless type, interconnect with the wireless fire alarm panel;

Photoelectric smoke detector including battery and bracket;