Home use Carbon monoxide detector Parameters Remarks
carbon monoxide detector, toxic gas detector, CO detector

Model:AHC-1

1.Semiconductor sensor
2.Operating voltage:3 batteries;
3.Wall/Ceiling mounted;
4.Alarm output: Sound&Flash alarm;
5.Alarm level:
>500PPM CO between 3 minutes;
>100PPM CO between 10-40 minutes;
>50PPM CO between 60-90 minutes;
6.Alarm density: 50(+30%~-30%)ppm CO;
7.backlit LCD display
8.Malfunction auto-check indicator
9.Dimension: Φ108*38mm .
10.Execute criterion:GB15322;EN50291;UL2034

Independent CO Detector with LCD display

Batteries driven

carbon monoxide detector, toxic gas detector, CO detector

Model:AHC-2

1.Semiconductor sensor;
2.Operating voltage: 85-265V AC(can support 9V back up battery); Wall mounted;
3.Alarm output: Sound&Flash alarm;
4.Alarm level: 150PPM±80PPM.
5.Drivable accessaries: electromagnetic valve & exhaust fan;
6.High Reliability sensor;
7.MCU processing adopted,SMT adopted,good stability
8.Malfunction auto-check indicator
9.Dimension: 118.5*82*43mm .
10.Execute criterion:GB15322;EN50291;UL2034

Independent CO Detector

AC driven or batteries driven

carbon monoxide detector, toxic gas detector, CO detector

Model:AHC-3

1.Japan FIGARO electrochemical sensor
2.Operating voltage: 120/230V AC (can support 9V back up battery); Wall mounted;
3.Alarm output: Sound&Flash alarm;
4.Alarm level:
>400PPM CO between 4-15 minutes;
>150PPM CO between 10-50 minutes;
>70PPM CO between 60-240 minutes;
5.Drivable accessaries: electromagnetic valve & exhaust fan;
6.High Reliability sensor;
7.MCU processing adopted,SMT adopted,good stability
8.Malfunction auto-check indicator
9.Dimension: 118.5*82*43mm .
10.Execute criterion:GB15322;EN50291;UL2034

Independent CO Detector with LCD display (FIGARO electrochemical sensor)

Nemoto electrochemical sensor is optional.

AC driven or batteries driven

carbon monoxide detector, toxic gas detector, CO detector

Model:AHC-4

1.Semiconductor sensor;
2.Operating voltage: 220V AC;DC12-24V; Wall/Ceiling mounted;
3.Alarm output: Sound&Flash alarm; NO/NC output;
4.Static Power Consumption:<2W; Alarm Consumption:<4W;
5.Response recovered:<200seconds;
6.High Reliability sensor;
7.MCU processing adopted,SMT adopted,good stability
8.Malfunction auto-check indicator
9.Dimension: 110*80*40mm .
10.Execute criterion:GB15322;EN50291;UL2034

AC driven
carbon monoxide detector, toxic gas detector, CO detector

Model:AHC-5

1.Operatin voltage:DC3V(2*1.5V AA alkaline batteries)
2.Static current:≤60uA
3.Alarm current:≤25mA
4.Sensitivity:150PPM±50PPM
5.Soudlevel:85dB/3m
6.Installation:Ceiling mounted
7.Working environment:-10℃~+50℃(≤95%RH No congelation)
8.Dimension:Φ110*45mm

Independent CO Detector

Battery driven