Industrial Carbon Monixide detector series Parameters Remarks
toxic gas detection system, toxic gas detector

Toxic Gas Transmitter: Type:AIC-1

Detect Gas: Toxic gas, Carbon monoxide, CO, Oxygen;
1. Enivronmental parameter:
temperature: -20℃~+50℃
RH: ≤90% (Non-condensing)
2. Technical parameter:
Working voltage: 16~30VDC
Working current: 120mA
Output signal: 4~20mA standard signal with 3-wire system output, RS485 outputs;
3. Sensor: Electrochemical sensor
4. Response time: T9 less than 30 seconds
5. Effect range: 0-100%LEL
6. Installation parameter:Wall mounting type
Transmission cable: three-core shielded cable
7. Section: 3×1.5sqmm, outer diameter: ¢10mm
Transmission range: ≤1000m
8. Class of explosive-proof:
Exd IICT6Gb (explosive insulation); ExiaIICT4 (Intrinsically Safe application)
9. Grade of Protection:IP65
10. Connector: G1/2 (Insidethread)
11.Size:183*143*92mm


Working with control panel AIG-P1
toxic gas detection system, toxic gas detector

Gas Transmitter: Type:AIC-2

Detect Gas: Toxic gas, Carbon monoxide, CO, Oxygen;
1. Enivronmental parameter:
temperature: -20℃~+50℃
RH: ≤90% (Non-condensing)
2. Technical parameter:
Power consumption:<3W;
Output signal: 4~20mA standard signal with 3-wire system output, RS485 outputs;NO/NC signal to DCS, PLC optional
3. Sensor: Electrochemical sensor
4.Display method: LED display to indicate index of density of the gas
5. Effect range: 0-100%LEL
6.Grade of Protection:IP65
7.Transmission range: ≤1000m
8. Class of explosive-proof:
Exd IICT6Gb (explosive insulation);
9. Grade of Protection:IP65
10.Debug method: IR remote

Working with control panel AIG-P1
toxic gas detection system, control panel

Type:AIG-P1

Carbon monoxide detection control panel/Toxic gas detection control panel;Gas detector control panel

Detect Gas: LPG, Natural gas, Combustible gas, Flammable gas; Toxic gas; Carbon monoxide;

1.Range type: %LEL, %VOL, PPM
2.Alarm level: 2 levels alarms, set by user
3.Preset level:(EX)low alarm:25%LEL; High alarm: 50%LEL;
4.Display method: LED display indicates the value of density , status of alarm or fault.
5.Input: 4-20ma input, RS485 addressable input
6.Installation type:Wall mounted
7. Communications:
(1)Conventional type: 2,4,8 Channels, 4-20mA input;
(2)Addressable type:12, 16, 24, 32 protection zones, RS485 input
8.Working environment:-20℃~+50℃ RH: ≤90% (Non-condensing)
9.Working voltage: AC220 50Hz
10.Power consumption: Control Panel: 6W max, Detector: 1W max;
10.Execute criterion:GB16808-1997

Both suitable for LPG, Natural gas, Toxic gas

AIC-1, AIC-2 compatible